We accept NHS purchase orders

Vitalograph Respiratory Monitor copd-6 USB
The copd-6 usb identifies those at risk of COPD at the pre-symptomatic stage to allow early medical intervention and facilitate better clinical outcomes. It combines all the features of the COPD-6 with the ability to link to your PC to generate electronic and hard copy reports through Vitalograph Reports software. Session data and device ID may be transmitted to Vitalograph Reports or an API developers' kit is available for providers of e-Diary, home hub and telemedicine solutions.
This pioneering device screens out those whose FEV1 is normal, and who therefore do not have COPD, without the risk of false COPD negatives.
By linking to your PC the copd-6 usb produces electronic & hard copy reports.
- Predicted values, 3 test results, best test, % predicted and lung age automatically tabulated;
- Obstructive index, COPD (GOLD) Classification indicator;
- BMI calculated;
- Blow quality indicator;
- Interpretation of results;
- Automatically sends data after each blow;
- Can also send session data;
- Time and date of each session;
- Indicates blow quality and number of blows in each session;
Reports Include:
- Single page record for screening or monitoring;
- Various report options;
- Optional subject ID and name fields (weight field optional);
- Ability to add comments to the report;
- Age, height, gender, device ID, time/date fields automatically populated;
- Can automatically name the PDF file;
- Ability to add comments to the report;
Transmits:
- FEV1, FEV6 and FEV1/FEV6;
- Predicted values for the above;
- Age, gender and height;
- Device ID automatically transmitted with the data;
Technical Specification
Product: | Vitalograph copd-6 USB |
Model Number | 4000 |
Part Number | 40200, 40450, 40350, 40850 |
Description | Vitalograph copd-6, Vitalograph copd-6 usb, Vitalograph copd-6 bluetooth, Vitalograph copd-6 serial |
Parameters Displayed | FEV1/FEV6/ratio and % predicted |
Quality of Blow Indicator | Yes |
Obstructive Index | Mild, Moderate, Severe (FEV1% predicted) |
COPD Classification | Normal (not COPD); Stage I, II, III & IV (FEV1% predicted) |
Lung Age Indicator | Yes |
Flow Impedance | Better than 0.15 kPa/L/s at 14 L/s |
Operating Temperature Range | 17 - 37°C |
Sensor | Stator rotor |
Accuracy | Better than +/- 3% |
Range | 0 - 9.99 L BTPS |
Size | 113 x 63 x 48mm |
Weight | 55g net |
Display | Custom Liquid Crystal Display |
Power | AAA batteries |
Performance Standards | ISO 26782:2009 ISO 23747:2007 ATS/ERS 2005 |
Safety Standards | IEC 60601-1:2005 |
Medical Safety Standard | Medical Devices 93/42/EEC (as amended) |
Designed and manufactured to following QA/GMP standards | ISO 13485:2003 FDA 21CFR820 |